Measurements of Fire Loads and Calculations of Fire Severity

Authors

  • D. Gross

Keywords:

Fire load, fuel load, fire growth, heat release, combustion, computer models, fire severity, fire endurance

Abstract

Types of furnishings, interior finish, and occupancy trends have changed considerably over the last several decades, so new fire load surveys for various occupancies are being conducted in various countries, using modern surveying techniques. These new data can be used to calculate fire growth curves, considering modern lightweight methods of construction using large window areas and mechanical ventilation. Computer models are designed to evaluate fire growth as a dynamic process, using such factors as heats of combustion, changing temperature levels, combustion enthalpy per unit mass of air, thermal conductivities and radiation, furniture arrangements and collapse during fires, etc. As these computational methods become more refined, changes in fire endurance testing can be made to produce more realistic results, which may represent fire exposures and potential fire severities different than those we are familiar with.

References

Babrauskas, V. 1976. Fire endurance in buildings. UCB FRG 76-16. Univ. Calif., Berkeley.nBabrauskas, V., and R. B. Williamson. 1975. Post-flashover compartment fires. UCB FRG 75-1. Univ. Calif., Berkeley.nBaldwin, R., M. Law, G. Allen, and L. G. Griffiths. 1970. Survey of fire-loads in modern office buildings-some preliminary results. FR Note 808. Fire Research Station. Dorehamwood, Herts, England.nBerggren, K., and U. Erikson. 1970. Brand-belastning i Kontorhus Statistisk Inventering och Utvardering. Rapport 18:1. Stalbyggnads-institutet. Stockholm.nBonetti, M., P. Kree, and J. Kruppa. 1975. Estimation des Charges Modiliere d'Incendie dans les Immeubles a Usage de Bureaux. Construction Metallique. No. 3.nBryson, J. O., and D. Gross. 1975. Techniques for the survey and evaluation of live floor loads and fire loads in modern office buildings. BSS 16. Nat. Bur. Stand. Washington, D.C.nConvention Europeene de la Construction Metallique. 1974. Fire safety in constructional steelwork. Report CECM III-74-2E.nCoward, S. K. D. 1975. A stimulation method for estimating the distribution of fire severities in office rooms. Build. Res. Estab. Current Paper CP 31/75.nCroce, P. A. 1975. A study of room fire development: the second full-scale bedroom fire test of the home fire project. FMRC Serial 21011.4, RC 75-T-31. Factory Mutual Research Corp. Norwood, MA.nCulver, C. G. 1976. Survey results for fire loads and live loads in office buildings. BSS 85. Nat. Bur. Stand. Washington, D.C.nCulver, C. G., and J. Kushner. 1975. A program for survey of fire loads and live loads in office buildings. Tech. Note 858. Nat. Bur. Stand. Washington, D.C.nEmmons, H. W. 1977. Computer fire code (II). Home Fire Project Tech. Rep. 20. Harvard Univ. Cambridge, MA.nForsberg, U., and J. Thor. 1971. Brand-belastningsstatstik for Skolar och Hotell. Rapport 44:1. Stalbyggnadsinstitutet. Stockholm.nIngberg, S. H. 1928. Tests of the severity of building fires. Quarterly Rep. Nat. Fire Prot. Assoc.22:43-61.nIngberg, S. H., J. W. Dunham, and J. P. Thompson. 1957. Combustible contents in buildings. Report BMS 149. Nat. Bur. Stand. Washington, D.C.nKawagoe, K. 1958. Fire behavior in rooms. Report 27. Build. Res. Inst. Tokyo.nKawagoe, K. 1967. Estimation of fire temperature-time curve in rooms. Research Paper 29. Build. Res. Inst. Tokyo.nKawagoe, K., and T. Sekine. 1963. Estimation of fire temperature-time curve in rooms. BRI Occasional Report 11. Build. Res. Inst. Tokyo.nLaw, M. 1971. A relationship between fire gradings and building design and contents. Joint Fire Res. Org. Fire Res. Note 877.nLie, T. T. 1974. Characteristic temperature curves for various fire severities. Fire Tech.10(4):315-326.nMagnusson, S-E., and O. Pettersson. 1972. Brandteknisk Dimensionering av Stalkonstruk-tioner. Chapt. 8 in Norrbottens Jarnverks AB Stalhandbook. Lulea.nMagnusson, S-E., and S. Thelandersson. 1970. Temperature-time curves of complete process of fire development, Theoretical study of wood fuel fires in enclosed spaces. Acta polytechnia Scandanavia Civil Eng. Const. Ser. 65.nNilsson, L. 1970. Fire loads in flats. Report R34. Statens Institut for Byggnadsforskning. Stockholm.nOdeen, K. 1963. Theoretical study of fire characteristics in enclosed spaces. Bulletin 10. Division of Building Construction. Royal Inst. Tech. Stockholm.nPape, R., J. Mavec, D. Kalkbrenner, and T. Waterman. 1976. RFIRES program documentation and users guide-semistochastic approach to predicting the development of a fire in a room from ignition to flashover. Report to Nat. Bur. Stand. ITT Res. Inst.nReeves, J. B., and C. D. MacArthur. 1976. Dayton aircraft cabin fire model. FAA-RD-76-120. Univ. Dayton Res. Inst.nRobertson, A. F., and D. Gross. 1970. Fire load, fire severity, and fire endurance. ASTM Special Tech. Pub.464:3-29.nRockett, J. A. 1969. Objectives and pitfalls in the simulation of building fires with a computer. Fire Tech.5:311-322.nRodak, S., and S. H. Ingberg. 1967. Full-scale residential occupancy fire tests of 1939. Un-publ. Rep. Nat. Bur. Stand. Washington, D.C.nSuperintendent of Documents. 1942. Fire resistance classifications of building constructions. Building Mater. Struct. Rep. 92. Washington, D.C.nTsuchiya, Y., and K. Sumi. 1971. Computation of the behavior of fire in an enclosure. Combustion and Flame16:131-139.nWitteveen, J. 1966. Brandveiligheid Staalcon-structies. Centrum Bouwen in Staal. Rotterdam.n

Downloads

Published

2007-06-05

Issue

Section

Research Contributions